STM32: fix timers
- Correctly synchronize TIM2 & TIM5 for correct ICG and SH clocks
This commit is contained in:
@@ -198,7 +198,7 @@ static void MX_ADC1_Init(void)
|
||||
hadc1.Init.ClockPrescaler = ADC_CLOCK_SYNC_PCLK_DIV4;
|
||||
hadc1.Init.Resolution = ADC_RESOLUTION_12B;
|
||||
hadc1.Init.ScanConvMode = DISABLE;
|
||||
hadc1.Init.ContinuousConvMode = ENABLE;
|
||||
hadc1.Init.ContinuousConvMode = DISABLE;
|
||||
hadc1.Init.DiscontinuousConvMode = DISABLE;
|
||||
hadc1.Init.ExternalTrigConvEdge = ADC_EXTERNALTRIGCONVEDGE_RISING;
|
||||
hadc1.Init.ExternalTrigConv = ADC_EXTERNALTRIGCONV_T4_CC4;
|
||||
|
||||
Reference in New Issue
Block a user